Sign In to Your Account

 

Don't have an account yet? Click here to signup.

Forgot Password? Click here to retrieve it.

Sales & Tech Support: 231-935-4044

EOT 70W Fiber Laser Isolator Data Sheet

 EOT 70W Fiber Laser Isolators

EOT’s 70W Fiber Laser Isolators have been specifically designed for pulsed Yb Fiber Lasers used in marking and engraving applications. Marking and engraving of highly reflective metals can result in large levels of back reflection, creating the potential for non-optimal performance of the laser or even damage to the laser. This can result in unacceptable marking quality and significant down time. Utilizing high damage threshold optics, these isolators provide for high transmission of light in the forward direction and strong attenuation of light traveling in the reverse direction. Designed specifically for harsh, industrial environments, an integrated beam expanding telescope assures excellent beam pointing stability and beam quality, which is required to assure high quality marking and engraving.

Benefits:

· Rugged, environmentally hardened assembly assures limited down time for marking systems due to laser problems

· Minimal beam distortion results in clear, distinct part marking

Features:                                

· Critical components are designed to minimize return loss which can degrade laser performance

· Proper steering and heat sinking of backward traveling light assures isolator performance does not degrade over time due to heating

· Protective armor cabling for fiber is standard

· U.S. Patent 7,306,376; other patents applied for

Specificationsa:

Part Number
110-10353-0001
Fiber Typesb
Contact EOT 
Maximum Incident Average Power (W)
70
Center Wavelength (nm)
1065 ± 15
MDegradation (%)
<10
Standard Output Beam Diameter (1/e2, mm)c
7.5 ± 1.5
Insertion Loss of light through fiber core (dB)c
<0.5
Isolation at 10-50°C (dB)
>20
Isolation at 30°C (dB)
>27
Return Loss (dB)
<-50
Reverse Power Handlingd
77W for 90sec. max.
Maximum Pulse Energy (mJ)
1
Peak Power (kW) 20
Operating Temperature (°C)
10-50
Storage Temperature (°C)
-10-70
Storage Humidity, non-condensing (%)
10-90

a Product specifications are subject to change.

b Standard fiber length is 3m, protective Teflon tubing length is 2.15m in a 2m armor cable jacket. Customers should contact EOT regarding other fiber requirements.

c Insertion loss of light through fiber cladding is not included in the insertion loss specification.

d Case temperature ≤50ºC. 

Note: All products are RoHS compliant.

**It is recommended that the isolator be attached to the laser enclosure using a compression fitting that secures only the outer, metal-reinforced jacket. The inner PTFE tube is meant as an abrasion barrier for the optical fiber and should be allowed to move freely with the fiber.